Serial dilution cheat sheet

Everything you need to plan an N-step dilution ladder from a stock, in one page.

The identities

Starting from a stock C0C_0, after N uniform D-fold dilutions:

CN=C0DNC_N = \dfrac{C_0}{D^N}

To reach a target concentration CNC_N in exactly N steps, solve for the per-step factor:

D=(C0CN)1/ND = \left(\dfrac{C_0}{C_N}\right)^{1/N}

Each step transfers Vstep/DV_{\text{step}}/D of solution from the previous tube into fresh diluent, so the total volume per tube stays fixed at VstepV_{\text{step}}:

Vtransfer=VstepDV_{\text{transfer}} = \dfrac{V_{\text{step}}}{D}

Stock consumed total = N⋅VtransferN \cdot V_{\text{transfer}}. Diluent used per step = Vstep−VtransferV_{\text{step}} - V_{\text{transfer}}.

Common ladders

LadderD per stepSteps to 10⁶-foldTransfer (per 100 µL step)Notes
1:222050 µL into 50 µL diluentAntibody titers, IC₅₀ dose-response
1:3312.6 (round up)33 µL into 67 µL diluentUneven; use for dose response with 3-fold steps
1:558.620 µL into 80 µL diluentCompromise between resolution and step count
1:1010610 µL into 90 µL diluentDefault choice — clean powers of 10
1:10010031 µL into 99 µL diluent1 µL is at the P2 floor — prefer 1:10

The 1:10 ladder is the workhorse: powers of 10 are easy to reason about, transfers stay comfortably in P20 range, and 6 steps hits the 10⁶-fold dilutions common in microbiology (CFU counts) and PCR (standard curves).

Pipette accuracy floors

Every pipette has a low-end below which the CV climbs. Below these values, spread across replicate transfers is ≥ 5 % and you should split the step further.

PipetteRangeAccurate down toDo not use below
P20.1 – 2 µL0.2 µL0.1 µL
P10 (if available)0.5 – 10 µL1 µL0.5 µL
P202 – 20 µL2 µL1 µL
P10010 – 100 µL10 µL5 µL
P20020 – 200 µL20 µL10 µL
P1000100 – 1000 µL100 µL50 µL

When to serial dilute

Any time a one-step C1V1=C2V2C_1V_1 = C_2V_2 would call for a stock volume below the smallest pipette’s accurate floor. Rough test:

Choosing N

Two constraints trade off:

Heuristic. Pick the smallest N such that every step’s transfer volume is ≥ 2× the pipette floor. For most 10⁶ dilutions, that lands on N = 6 with D = 10.

Diluent volume trick

For a step volume of VstepV_{\text{step}} and a dilution factor of D:

Vdiluent=Vstep−Vtransfer=Vstep⋅(1−1D)V_{\text{diluent}} = V_{\text{step}} - V_{\text{transfer}} = V_{\text{step}} \cdot \left(1 - \dfrac{1}{D}\right)

For a 1:10 ladder at 100 µL steps: Vdiluent=100⋅0.9=90V_{\text{diluent}} = 100 \cdot 0.9 = 90 µL. For a 1:2 ladder at 100 µL steps: Vdiluent=100⋅0.5=50V_{\text{diluent}} = 100 \cdot 0.5 = 50 µL.

Common mistakes

  1. Not vortexing / not changing tips between steps. Carryover of stock down the ladder inflates every subsequent concentration. Change tips.
  2. Pipetting below the pipette floor. A 0.5 µL transfer with a P20 has ≥ 10 % CV. Split into two steps instead.
  3. Mismatched step volumes. If VstepV_{\text{step}} isn’t constant across the ladder, D per step isn’t either, and the analytical formula CN=C0/DNC_N = C_0/D^N silently breaks. Every step must use the same volume, or you must track each V1V_1/V2V_2 pair separately.
  4. Not accounting for compound stickiness. Peptides, hydrophobic small molecules, and DMSO stocks can lose 5–20 % to plastic surfaces per step. Consider low-bind tubes or a carrier protein.

Sources

  • Rainin RC-500 / RC-1000 pipette specifications — accuracy tables
  • Gilson Pipetman NEO product spec sheet — CV at low-end volumes
  • Harris, Quantitative Chemical Analysis, 10th ed. (2020), §2-2 — analytical precision