Half-Life Calculator — First-Order Kinetics & Decay

Half-life is the time it takes for half of a decaying substance — a radioactive nuclide, a first-order chemical reactant, a plasma-drug concentration — to disappear. For a first-order process the number is deceptively simple: t½ = ln(2)/k, independent of how much you started with. That single-number characterisation is why chemists, physicists, and pharmacokineticists all reach for it.

Half-Life Calculator

First-order kinetics by default (radioactive decay, most drug clearance, many nuclear and biochemical decays). Switch order for zero- or second-order integrated rate laws. Time and rate units freely mixed — the math runs in SI internally.

Reaction order
Mode
Solve for

Full rate laws for all three orders are rendered in Show the work once you compute. Intermediate arithmetic runs in SI (seconds, mol L⁻¹); display units convert at the boundary. ln 2 = 0.693 147 180 559 945 (mathematical identity, exact).

The first-order integrated rate law

If species A disappears at a rate proportional to how much of it is present — the differential rate law −d[A]/dt = k[A], with k in s⁻¹ — separating variables and integrating from time 0 to t gives the integrated rate law

[A]t=[A]0 e−kt,t1/2=ln⁡2k[A]_t = [A]_0 \, e^{-k t}, \quad t_{1/2} = \dfrac{\ln 2}{k}

Notice that [A]₀ drops out of t½. That is the key insight of first-order kinetics: the time it takes for the concentration to halve is the same no matter how far along the reaction is. From 1.0 M → 0.5 M takes as long as from 0.001 M → 0.0005 M.

When the initial amount does matter

For zero- and second-order reactions it does. The integrated forms and half-lives are:

OrderIntegrated rate lawHalf-life
Zero[A]ₜ = [A]₀ − k tt½ = [A]₀ / (2k)
First[A]ₜ = [A]₀ · exp(−k t)t½ = ln 2 / k
Second1/[A]ₜ − 1/[A]₀ = k tt½ = 1 / (k [A]₀)

Watch the units of k carefully — they carry the order information. First-order k has units of s⁻¹; zero-order has M·s⁻¹; second-order (single reactant, r = k[A]²) has M⁻¹·s⁻¹. If a textbook problem quotes k without units, it is almost always because the author is being sloppy — clarify before plugging in.

Radioactive decay is first-order

Every unstable nuclide decays with a rate proportional to how many nuclei are left, so radioactive decay is always first-order and the half-life is a fixed property of the nuclide. Common examples, all values from NNDC or NIST:

NuclideHalf-life
¹⁴C (carbon-14)5,700 ± 30 y (NIST) — 5,730 y (Cambridge)
⁹⁹ᵐTc (technetium)6.0072 h
¹³¹I (iodine)8.0252 d
²³⁸U (uranium)4.468 × 10⁹ y
³H (tritium)12.32 y

The “decay constant” λ is exactly the first-order rate constant k in nuclear physics notation. Activity (disintegrations per second) tracks the number of nuclei: A(t) = λ N(t) = A₀ · exp(−λ t). You can therefore work the math on either.

Worked example 1 — first-order chemistry

A reactant A decomposes by first-order kinetics with k = 2.3 × 10⁻³ s⁻¹ and [A]₀ = 0.500 M. What is [A] after 300 s?

Worked example — [A] at 300 s
k
2.3 × 10⁻³ s⁻¹
[A]₀
0.500 M
t
300 s
  1. Formula
  2. Substitute
  3. Note

    k·t = 0.69, one natural log below zero — so [A] falls to about half of [A]₀. That's not a coincidence: 300 s is very close to the half-life, t½ = ln(2)/k = 301.4 s.

  4. Result

Worked example 2 — carbon-14 dating

An organic sample retains 25 % of the ¹⁴C activity of a modern reference. How old is it?

Worked example — 25 % of modern ¹⁴C
f = A_t/A_0
0.25 (25 %)
t½ (¹⁴C, NIST 2015)
5,700 y
  1. Formula
  2. Substitute
  3. Note

    Two half-lives elapsed: 100 % → 50 % → 25 %. The answer is exactly 2·t½, independent of the specific t½ value you pick — dating with the Cambridge value 5,730 y gives 11,460 y; with the Libby value 5,568 y gives 11,136 y. The convention matters when comparing published radiocarbon results.

  4. Result

Choosing the right half-life for ¹⁴C

The literature has three values for the ¹⁴C half-life in circulation, and mixing them is a common source of error:

  • 5,568 y (“Libby half-life”, 1949) — Willard Libby’s original measurement, still the conventional half-life used to report radiocarbon ages so historical dates stay comparable across the calibration curves (IntCal, SHCal).
  • 5,730 ± 40 y (“Cambridge half-life”, Godwin 1962) — a revised measurement widely adopted in physics and geology textbooks.
  • 5,700 ± 30 y (NIST 2015) — the currently best-measured value, and what you should use for a “true” age from first principles.

For classroom exercises use 5,700 y or 5,730 y. For anything you will compare to a published radiocarbon date, keep 5,568 y and report ages in “conventional radiocarbon years BP” — the calibration curves already account for the offset.

Common pitfalls

  • Zero-order half-life depends on [A]₀. Don’t quote t1/2=ln⁡2/kt_{1/2} = \ln 2 / k for a zero-order enzyme reaction.
  • Rate-constant units carry the order. A quoted kk with the wrong unit label is a strong signal the reaction is not first-order — check.
  • Fraction remaining vs. fraction reacted. “20 % of the original remains” is f=0.20f = 0.20; “the reaction is 80 % complete” is the same physical situation. Confusing the two in time-to-fraction mode is the most common calculator misuse — this tool asks for fraction remaining.
  • Year conventions. This calculator uses the Julian year (1 yr = 365.25 d = 31,557,600 s exactly), which matches NIST SP 811 and the IAU 1976 convention adopted by NNDC for radiological half-lives. Do not confuse with the tropical (365.24219 d) or Gregorian (365.2425 d) year for these purposes.

Frequently asked questions

Why doesn't first-order half-life depend on the initial amount?
For a first-order process the rate is proportional to how much reactant (or radioactive nuclide) is present: r = k[A]. Solving the differential equation gives [A]_t = [A]_0 · exp(−k·t), so the ratio [A]_t/[A]_0 depends only on k·t — the [A]_0 cancels. The time for the ratio to fall to 1/2, t_½ = ln(2)/k, therefore involves only k. Zero- and second-order half-lives DO depend on [A]_0 (t_½ = [A]_0/(2k) for zero-order; t_½ = 1/(k[A]_0) for second-order), and that is one way to identify the order experimentally: if repeated measurements of t_½ change as [A]_0 changes, the reaction is not first-order.
What is the difference between activity and amount for radioactive decay?
The number of radioactive nuclei N is the *amount* of material; the activity A = −dN/dt = λ·N is the number of disintegrations per second (measured in becquerels, Bq, or curies, 1 Ci = 3.7 × 10¹⁰ Bq). Both decay with the same half-life because λ (the decay constant) is a constant of the nuclide. So A_t/A_0 = N_t/N_0 = exp(−λ·t) = (1/2)^(t/t_½). You can therefore work the arithmetic in whichever the problem gives you — a mass, a mole count, or an activity — and this calculator's math is identical.
How is radioactive decay related to first-order chemical kinetics?
Both are described by the same differential equation: the rate is proportional to the amount present. For chemistry that's r = k[A] with rate constant k in s⁻¹; for a radionuclide it is dN/dt = −λN with decay constant λ in s⁻¹. The two constants play identical mathematical roles, and t_½ = ln(2)/k = ln(2)/λ. The physical mechanism is different — quantum-mechanical tunneling out of a nuclear potential well vs. classical activation-energy barrier crossing — but the observable macroscopic law is the same.
When does the half-life formula not apply?
The clean t_½ = ln(2)/k relation is a first-order result. Zero-order and second-order integrated rate laws produce concentration-dependent half-lives (see the equation panel above). Complex mechanisms — reversible reactions near equilibrium, autocatalytic reactions, chain reactions, saturable enzyme kinetics — do not admit a single half-life at all: the apparent t_½ changes as the reaction progresses. If your reactant is not decaying exponentially, no single number of the form 'ln(2)/k' will describe it. For radioactive decay, the exponential law is exact (a first-order quantum-mechanical process); for chemistry, verify first-order behaviour by plotting ln[A] vs. t and checking that the line is straight.
Which value should I use for the carbon-14 half-life?
Radiocarbon dating uses two conventions. The 'Libby half-life' 5,568 y (Libby 1949) is embedded in the calibration curves and reported ¹⁴C ages by convention — you keep using it so historical results stay comparable. The 'Cambridge half-life' 5,730 ± 40 y (Godwin 1962; adopted widely in physics texts) is closer to the modern best measurement. NIST's evaluated 2015 value is 5,700 ± 30 y. For teaching and back-of-envelope work, use 5,700 or 5,730 y; for anything you'll compare to a published radiocarbon calibration, keep 5,568 y as the conventional half-life and report the age as 'conventional radiocarbon years BP'.

Sources

Last updated: .